Increase Reliability & Resilience

Reduce strain on overloaded feeders by keeping phase imbalance from pushing any single phase toward its thermal limit, so equipment isn’t carrying excess stress and reconfigurations aren’t constrained.

Switched Source’s distribution automation technology dynamically balances phase and circuit loading, supporting faster reconfiguration and strengthening fault location, isolation, and service restoration (FLISR) performance during both normal operations and contingency events.

Grid Conditions Can Change Instantly

Faults, lateral outages, severe weather, and planned maintenance all change how load is distributed across the system, often within seconds.

When operators need to move load, the limiting factor is frequently a single phase rather than the circuit as a whole. A transfer that the feeder could carry in aggregate gets blocked because one phase would exceed its thermal limit, which narrows switching options and slows restoration. Switched Source technology balances load across phases as the configuration changes, so transfers can be made without creating a new overload.

Call us when...

FLISR is constrained by single-phase limits rather than by total feeder capacity.

Phase imbalance is driving thermal stress and equipment wear.

A circuit needs more switching flexibility than its current configuration allows.

What You Unlock Over Traditional Solutions

Utilities have historically managed these conditions through carefully planned contingency switching, conservative transfer limits, extending three-phase infrastructure, and upgrading constrained lines.

While these remain necessary in many situations, Switched Source technology adjusts load dynamically as conditions change and operates alongside existing protection schemes rather than requiring changes to them. It rebalances automatically through planned and unplanned reconfigurations, so crews are not manually rebalancing during a storm and operators are not holding back transfers to stay within phase limits.

Riding Through Reconfiguration

CASE STUDY · NEW YORK IOU

When one of our utility partners in New York reconfigured a circuit for 10 hours of maintenance, the Phase-EQ kept rebalancing load in real time through the entire event, with no operator involvement. Across multiple installations, it has also stayed online through severe weather and both planned and unplanned reconfigurations.

By relieving the load and neutral-current limits that constrain FLISR schemes, it lets automated restoration pick up additional customers in as little as 5 minutes instead of an hours-long outage. Modeling shows 10 to 20% of a circuit can be restored faster this way.

SubstationLTC ZoneLTCRRSLPTLine Reg 1SwitchCapSwitchCapSwitchCapSwitchCapSLPTLine Reg 2RRRSLPTLine Reg 3SwitchCapSwitchCapSwitchCapSwitchCap12KV Feeder 112KV Feeder 2
SubstationLTC ZoneLTCRRSLPTLine Reg 1SwitchCapSwitchCapSwitchCapSwitchCapSLPTLine Reg 2RRRSLPTLine Reg 3SwitchCapSwitchCapSwitchCapSwitchCapPhase-EQ12KV Feeder 112KV Feeder 2